INSTALLATION
WARNING: A qualified service person must
install appliance. Follow all local codes.
NOTICE: State or local codes may only allow
operation of this appliance in a vented con-
figuration. Check your state or local codes.
CHECK GAS TYPE
Use the correct type of gas (natural or propane/LP). If
your gas supply is not the correct gas type, do not
install appliance. Call dealer where you bought
appliance for proper type appliance.
WARNING: This appliance is equipped for either
natural gas or propane/LP gas but not both. Gas
type is indicated on the rating plate. Field
conversion is not permitted.
INSTALLATION AND CLEARANCES
WARNING: Maintain the minimum clearances. If
you can, provide greater clearances from floor
and adjoining wall.
MINIMUM CLEARANCE TO COMBUSTIBLE
MATERIALS
Side Wall 16",
Bottom: 0" (For Wood Burning Installation- Non-
Combustible Floor is Required)
WARNING: DO NOT PLACE UNDER A CEILING
OR OVERHANG.
CONNECTING TO GAS SUPPLY
WARNING: This appliance requires a 1/2"
NPT (National Pipe Thread) inlet connection
to the pressure regulator.
WARNING: A qualified service person must
connect appliance to gas supply. Follow all
local codes.
CAUTION: Never connect propane/LP fire
ring directly to the propane/LP supply. This
appliance requires an external regulator (not
supplied). Install the external regulator be-
tween the appliance and propane/LP supply.
WARNING: Never connect natural gas
fire ring to private (non utility) gas wells.
This gas is commonly known as
wellhead gas.
Installation Items Needed
Before installing appliance, make sure you have
the items listed below.
• external regulator (supplied by installer)
• piping (check local codes)
• sealant (resistant to propane/LP gas)
• equipment shutoff valve *
• test gauge connection *
• sediment trap
• tee joint
• pipe wrench
approved flexible gas line with gas connector
(if allowed by local codes) (not provided)
* An equipment shutoff valve with 1/8" NPT tap is
an acceptable alternative to test gauge
connection. Purchase the optional equipment
shutoff valve from your dealer.
For propane/LP units, the installer must supply
an external regulator. The external regulator will
reduce incoming gas pressure. You must reduce
incoming gas pressure to between 11" and 14" of
water. If you do not reduce incoming gas
pressure, appliance regulator damage could
occur. Install external regulator with the vent
pointing down as shown in Figure 2, page 6.